After an Implementation Engineer installs a new FlashArray and runs health checks, they see that Phonehome and Remote Assist are NOT working correctly.
Which outbound port needs to be open for all management ports (physical and virtual)?
A customer has purchased a FlashArray//XL. What power cables are required in order to connect this array to rack PDUs?
What command can be used to identify interface status?
Support requests a powercycle on a newly-installed FlashArray. What is the correct way to perform this action?
After upgrading Purity during a new installation, which command should an Implementation Engineer run to determine what version of Purity will be loaded at the next boot of the FlashArray?
Which default speed FC SFPs are shipped in FlashArray//XCR4 FC arrays?
What is the redundancy of the FlashArray//XL PSUs?
In a situation where FC cards need to be re-used during a controller upgrade, which is a valid transfer path?
What is the maximum number of DirectFlash Shelves supported for FlashArray//XL?
When performing an install on a FlashArray, what step should be taken first?
A data pack has been installed and the puredrive list command shows the drives in “unadmitted” status. Which command should be used to complete the admission?
A FlashArray arrives with Purity 5.3.8 applied out of the factory. The account team requests that the array configured with Purity 6.1.21. Which steps should the Implementation Engineer select to meet this requirement?
If a Technical Support Engineer (TSE) is not available to perform health checks after an installation, what action should the Implementation Engineer take?
Which action should an Implementation Engineer take to confirm that all volumes connected to a host are automatically in a protection group?
When installing the first DirectFlash Shelf on a FlashArray//XR2/3, what mezzanine ports are used on the controllers?
On a FlashArray//XR50R2/3 Fibre Channel (FC) array, what is the default type and placement of the PCIe FC card?
Which PCIe slot supports 4-port FC cards on FlashArray//XL?
After performing a hardware upgrade from an //M20R2 to a //X20R3-EMEZZ, a customer wants to add a Direct Flash Modules data pack to replace the existing SAS Chassis Data Packs (2x 20TB DPs). What extra hardware is required?
Which Purity command can be used to validate I/O is balanced across initiators?
What is the rack unit height of a FlashArray//XR2/3?
On a FlashArray//XR20R2/3 Fibre Channel (FC) array, what is the default type and placement of the PCIe FC card?
Before leaving the site after an install, who is required to provide completion sign-off?