Winter Sale - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: top65certs

NCSC-Level-1 Exam Dumps : Nutanix Certified Services Consultant (NCSC): Level 1

PDF
NCSC-Level-1 pdf
 Real Exam Questions and Answer
 Last Update: Nov 6, 2025
 Question and Answers: 78
 Compatible with all Devices
 Printable Format
 100% Pass Guaranteed
$29.75  $84.99
NCSC-Level-1 exam
PDF + Testing Engine
NCSC-Level-1 PDF + engine
 Both PDF & Practice Software
 Last Update: Nov 6, 2025
 Question and Answers: 78
 Discount Offer
 Download Free Demo
 24/7 Customer Support
$47.25  $134.99
Testing Engine
NCSC-Level-1 Engine
 Desktop Based Application
 Last Update: Nov 6, 2025
 Question and Answers: 78
 Create Multiple Test Sets
 Questions Regularly Updated
  90 Days Free Updates
  Windows and Mac Compatible
$35  $99.99

Verified By IT Certified Experts

CertsTopics.com Certified Safe Files

Up-To-Date Exam Study Material

99.5% High Success Pass Rate

100% Accurate Answers

Instant Downloads

Exam Questions And Answers PDF

Try Demo Before You Buy

Certification Exams with Helpful Questions And Answers

Nutanix Certified Services Consultant (NCSC): Level 1 Questions and Answers

Question 1

After finishing foundation on an AHV cluster, a consultant is preparing to plug into the customer network given the following set of requirements:

* All network traffic on trunks is tagged

* Customer is using LACP

* A native VLAN is not in use

Which set of commands should the consultant use to ensure cluster connectivity on customer equipment?

Options:

A.

change_cvm_vlan 0

ovs-vsctl set port br0 tag=0

ovs-vsctl set port br0-up bond_mode=balance-tcp

B.

change_cvm_vlan 10

ovs-vsctl set port br0 tag=10

ovs-vsctl set port br0-up bond_mode=balance-tcp

C.

change_cvm_vlan 0

ovs~vsctl set port br0 tag=0

ovs~vsctl set port br0-up bond_mode=active-backup

D.

change_cvm_vlan 10

ovs-vsctl set port br0 tag=10

ovs-vsctl set port br0-up bond_mode=balance-slb

Buy Now
Question 2

A consultant finishes creating a new ESXi cluster. The consultant connects to the nodes via laptop and a personal flat switch. The host/CVM network is on VLAN 23. The customer has the native VLAN on the ToR switches set to 23.

The customer wants to use LACP. Before placing the nodes on the customer network, the consultant tags VLAN 23 for each host and CVM. The consultant connects the nodes to the customer network and finds that they are unreachable.

What is causing this issue?

Options:

A.

The customer has LACP fallback enabled on switch ports.

B.

The hosts have not been migrated to a vSphere Distributed Switch.

C.

Under the vSwitch0 settings, the consultant did not select Route based on IP hash.

D.

The host and CVM are incorrectly configured.

Question 3

A consultant is onsite with a customer running Foundation VM (FVM) and discovers that there is no connectivity between the FVM and their laptop. The consultant verifies the following:

* The consultant’s laptop and Nutanix nodes are plugged into a flat switch.

* The laptop, switch and nodes are plugged into supported power supplies.

* The laptop network adapters and FVM are configured with their corresponding IP addresses.

What is the cause for the connectivity failure to the FVM?

Options:

A.

The switch is not plugged into the power supply.

B.

Desktop Firewall is blocking ping requests.

C.

Network cables are not connected.

D.

Laptop WiFi configured to use DHCP.