Labour Day Special - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: top65certs

Cisco 500-920 Dumps

Page: 1 / 2
Total 40 questions

Cisco Data Center Unified Computing Infrastructure Troubleshooting (DCITUC) Questions and Answers

Question 1

When troubleshooting a LAN connectivity issue, you notice a failed uplink from the Cisco UCS Fabric Interconnects to the upstream LAN switch. What two could be causing the issue? (Choose two )

Options:

A.

Misconfigured VLAN on the failed uplink

B.

Misconfigured QoS parameters on the failed uplink

C.

A port channel mismatch between the Fabric Interconnects and the upstream LAN switch

D.

A SFP Type mismatch between the Fabric Interconnects and the upstream LAN switch

E.

A port speed configuration mismatch between the Fabric Interconnects and the upstream LAN switch

Question 2

You are in the process of upgrading your UCS M3 Server to a newer UCS M4 Server. You associate the Service Profile to the new UCS Server, but it fails to boot You suspect of a failed boot hard drive. You check your RAID1 Boot LUN in UCS Manager, but see no error messages What could be causing the issue?

Options:

A.

The newer Cisco UCS M4 Server is using flash drives, not hard drives

B.

The newer Cisco UCS M4 Server is using disks of larger capacity than the previous UCS M3 Server

C.

A misconfiguration on the Service Profile Local Boot Policy

D.

A misconfiguration on the Service Profile Local Disk Policy

Question 3

What three options should be verified, when you are able to connect to Cisco UCS Manager, but unable to open a KVM session to a blade? (Choose three)

Options:

A.

Verify TCP port 2068 is not blocked by an ACL orFirewall

B.

Confirm the IP Address assigned to UCS Manager is the same as the KVM address

C.

Verify the KVM IP Address is on the same ip subnet as the virtual machines

D.

Confirm the KVM IP Address is added to the route table in Cisco UCS Manager

E.

Confirm the IP Address assigned to the KVM is not a duplicate IP

F.

Verify the KVM IP Address is on the same subnet as the Fabric Interconnect management address

Question 4

Which two statements describes connecting the IO Modules in the UCS chassis to the Fabric interconnects? (Choose two )

Options:

A.

Connect Fl-A to the IOM B of each chassis

B.

Connect Fl-B to IOM A and IOM B in each chassis

C.

Connect Fl-A to the IOM A of each chassis

D.

Connect Fl-A to IOM A and IOM B in each chassis

E.

Connect Fl-B to the IOM A of each chassis

F.

Connect Fl-B to the IOM B of each chassis

Question 5

Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?

Options:

A.

The server has a service profile assigned, but has connectivity issues with UCS Manager

B.

The server is not properly connected

C.

The server does not have a service profile assigned, but has been discovered by UCS Manager

D.

The server has been properly connected, but has not been discovered by UCS Manager

Question 6

Which Cisco UCS internal component maintains the UCS XML database, manages the FSM stages and operations and instructs the Application Gateway to perform operations on physical and logical elements?

Options:

A.

Cisco Data Management Engine

B.

Cisco UCS Manager

C.

Cisco Application Gateways

D.

Cisco Finite State Machine

Page: 1 / 2
Total 40 questions