Winter Sale - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: top65certs

VMware 5V0-21.21 Exam With Confidence Using Practice Dumps

Exam Code:
5V0-21.21
Exam Name:
VMware HCI Master Specialist
Vendor:
Questions:
66
Last Updated:
Nov 18, 2025
Exam Status:
Stable
VMware 5V0-21.21

5V0-21.21: VMware Certified Master Specialist - HCI 2021 Exam 2025 Study Guide Pdf and Test Engine

Are you worried about passing the VMware 5V0-21.21 (VMware HCI Master Specialist) exam? Download the most recent VMware 5V0-21.21 braindumps with answers that are 100% real. After downloading the VMware 5V0-21.21 exam dumps training , you can receive 99 days of free updates, making this website one of the best options to save additional money. In order to help you prepare for the VMware 5V0-21.21 exam questions and verified answers by IT certified experts, CertsTopics has put together a complete collection of dumps questions and answers. To help you prepare and pass the VMware 5V0-21.21 exam on your first attempt, we have compiled actual exam questions and their answers. 

Our (VMware HCI Master Specialist) Study Materials are designed to meet the needs of thousands of candidates globally. A free sample of the CompTIA 5V0-21.21 test is available at CertsTopics. Before purchasing it, you can also see the VMware 5V0-21.21 practice exam demo.

VMware HCI Master Specialist Questions and Answers

Question 1

As a part of a network hardware refresh project, all the network switches have been replaced with a newer, high-performance model. After the replacement, the company users started experiencing slowness on the applications hosted on their vSAN-backed VMs.

The vSAN administrator checked the vSAN Network Health status and noticed that the "Hosts large ping test" has failed.

What could be the cause of this performance degradation issue?

Options:

A.

MTU 9K is not configured on the hosts vSAN vMKernel ports.

B.

MTU 9K is not configured on the hosts VMnic ports.

C.

MTU 9K is not configured on the ToR switch.

D.

MTU 9K is not configured on the vDS switch.

Buy Now
Question 2

A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.

The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:

* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding

* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring

* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring

* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring

During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:

* Preferred Site - Preferred Site workloads should run on DC1 hosts.

* Secondary Site - Secondary Site workloads should run on DC2 hosts.

Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

Options:

A.

Change the Site Disaster Tolerance setting in Policy 3 to be “Dual Site Mirroring”.

B.

Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.

C.

Change the Site Disaster Tolerance setting in Policy 4 to be “None - Keep Data on Preferred”.

D.

Change the FTT setting in Policy 3 to be “Erasure Coding”.

E.

Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.

Question 3

An architect is currently working with a customer to transform their existing ESXi hosts to vSAN nodes. The customer expressed the following requirements.

• First phase will transform 50% of the hosts to a hybrid vSAN nodes.

• Second phase will transform the remaining 50% hosts to an All-Flash vSAN nodes.

The following constraint exists:

• Each host has a 4-port x 1 GbE network interface.

Which two recommendations should the architect make to align with the customer's requirements? (Choose two.)

Options:

A.

Hybrid vSAN clusters can have shared 1 GbE network adapters.

B.

All-Flash vSAN clusters must have dedicated 10 GbE network adapters.

C.

Hybrid vSAN clusters must have dedicated 1 GbE network adapters.

D.

All-Flash vSAN clusters can have shared 10 GbE network adapters.

E.

Hybrid vSAN clusters must have dedicated 10 GbE network adapters.