Big Cyber Monday Sale 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: save70

Huawei H13-624_V5.5 Exam With Confidence Using Practice Dumps

Exam Code:
H13-624_V5.5
Exam Name:
HCIP-Storage V5.5
Certification:
Vendor:
Questions:
106
Last Updated:
Dec 7, 2025
Exam Status:
Stable
Huawei H13-624_V5.5

H13-624_V5.5: HCIP-Storage Exam 2025 Study Guide Pdf and Test Engine

Are you worried about passing the Huawei H13-624_V5.5 (HCIP-Storage V5.5) exam? Download the most recent Huawei H13-624_V5.5 braindumps with answers that are 100% real. After downloading the Huawei H13-624_V5.5 exam dumps training , you can receive 99 days of free updates, making this website one of the best options to save additional money. In order to help you prepare for the Huawei H13-624_V5.5 exam questions and verified answers by IT certified experts, CertsTopics has put together a complete collection of dumps questions and answers. To help you prepare and pass the Huawei H13-624_V5.5 exam on your first attempt, we have compiled actual exam questions and their answers. 

Our (HCIP-Storage V5.5) Study Materials are designed to meet the needs of thousands of candidates globally. A free sample of the CompTIA H13-624_V5.5 test is available at CertsTopics. Before purchasing it, you can also see the Huawei H13-624_V5.5 practice exam demo.

HCIP-Storage V5.5 Questions and Answers

Question 1

A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on the storage devices. Which of the following statements is false about the engineer's configuration?

Options:

A.

If upper-layer services require high data security, the engineer needs to set the storage pool type to "Self-encrypting" when creating a converged storage pool.

B.

Before creating a converged storage pool, the engineer must enable the file service for nodes on DeviceManager.

C.

When creating a namespace, the engineer needs to select a security style and application type.

D.

When the storage network is a Remote Direct Memory Access over Converged Ethernet (RoCE) network, the engineer can run the "systemctl stop lldpad.service" command to disable the lldpad service.

Buy Now
Question 2

Assume a government customer purchased several Huawei scale-out storage devices for service deployment. An engineer needs to configure file services in standard protocol scenarios. Which of the following actions does not need to be performed by the engineer during the configuration?

Options:

A.

Install DPC.

B.

Create a converged storage pool.

C.

Create namespaces.

D.

Enable the file service for nodes.

Question 3

When delivering a flash storage project, Huawei engineers introduced the arbitration mechanism of HyperMetro to the customer. Which of the following statements is false about the arbitration modes?

Options:

A.

If no quorum server is configured, HyperMetro works in static priority mode. When an arbitration occurs, the preferred site wins the arbitration and provides services.

B.

In static priority mode, if the preferred site of a HyperMetro pair breaks down, the non-preferred site does not automatically take over HyperMetro services. As a result, the services stop, and the customer must forcibly start the services at the non-preferred site.

C.

In quorum server mode, the quorum server can be deployed only on physical machines and not on virtual machines.

D.

In quorum server mode, if the link between storage systems is down, each storage system sends an arbitration request to the quorum server.