Free and Premium NICET ITFAS-Level-1 Dumps Questions Answers

Inspection and Testing of Fire Alarm Systems Level I Exam Questions and Answers

Question 1

After successful completion of an inspection, who shall be responsible for maintaining the permanent records?

Options:

A.

AHJ

B.

Alarm contractor

C.

Fire marshal

D.

Owner

Buy Now
Question 2

How is a lead-acid battery inspected?

Options:

A.

By checking for damage

B.

By checking voltage

C.

By verifying specific gravity

D.

By verifying the charging circuit

Question 3

Which is true of the phone lines on a Digital Alarm Communicator Transmitter (DACT) when no other methods are in use?

Options:

A.

Phone lines must be dedicated.

B.

Primary line should be connected to the PSTN.

C.

Test signal must be sent every 24 hours.

D.

Two separate phone lines are required.

Question 4

What is the interval of a trouble signal test for retransmission to an off-premises location?

Options:

A.

Weekly

B.

Monthly

C.

Semiannually

D.

Annually

Question 5

In private mode systems, what is the audibility requirement?

Options:

A.

Minimum 75 dBA

B.

Minimum 85 dBA

C.

10 dBA above ambient

D.

15 dBA above ambient

Question 6

Where smoke detectors are installed for protection during construction, they shall be cleaned and verified to be within the marked sensitivity range before which event?

Options:

A.

Final cleaning

B.

Final commissioning

C.

Pre-test of system

D.

Walk-through by engineer

Question 7

When the main power is disconnected, how long should a power supply with emergency voice communication systems work in alarm mode?

Options:

A.

Maximum of 5 minutes

B.

Maximum of 15 minutes

C.

Minimum of 5 minutes

D.

Minimum of 15 minutes

Question 8

When is the elevator recall permitted to send a supervisory signal in lieu of an alarm signal?

Options:

A.

Where approved by the authority having jurisdiction

B.

Where approved by the building owner

C.

Where approved by the insurance company

D.

Where approved by the system designer

Question 9

Records of inspections, testing, and maintenance shall be provided in accordance with which section of NFPA 72?

Options:

A.

7.6.6

B.

7.8.2

C.

10.5.3

D.

14.6.3

Question 10

Within a fire alarm control unit, what is the maximum delay in seconds for alarm system responses after the initiation device has been activated?

Options:

A.

10

B.

15

C.

30

D.

60

Question 11

Lights used for fire alarm signaling shall be which of the following colors?

Options:

A.

Clear or amber

B.

Clear or blue

C.

Clear or nominal white

D.

Clear or red

Question 12

Which three of the following are types of fire alarm control units? (Choose three.)

Options:

A.

Central station

B.

Dedicated function

C.

Protected premises

D.

Releasing service

Question 13

With all notification appliances operating, what is the maximum sound pressure level, combined with the ambient sound pressure level, at the minimum hearing distance allowed by code?

Options:

A.

100 dBA

B.

105 dBA

C.

110 dBA

D.

115 dBA

Question 14

Inspection records for all systems shall be kept for which length of time?

Options:

A.

6 months

B.

5 years

C.

Until AHJ reviews records and 1 year

D.

Until the next test and 1 year

Question 15

The fire alarm control unit shows a supervisory signal on the display. What is the possible cause?

Options:

A.

A duct smoke detector is in alarm.

B.

A manual fire alarm box has been activated.

C.

A spot smoke detector is in alarm.

D.

A waterflow alarm has been activated.

Question 16

Which NFPA standard regulates how to perform the test of engine driven generator?

Options:

A.

NFPA 70

B.

NFPA 72

C.

NFPA 101

D.

NFPA 110

Question 17

An inspector is testing the ground-fault monitoring circuit on the control panel. How does the inspector perform this test?

Options:

A.

Remove the primary power to the main control panel.

B.

Remove the signaling line circuit from the main control panel.

C.

Verify presence of a ground fault with a meter using the ohm scale.

D.

Verify the ground-fault indication when circuits are grounded.

Question 18

In addition to 10% of devices not affected, what else must be tested when site-specific software is changed?

Options:

A.

10% of devices affected

B.

25% of devices affected

C.

50% of devices affected

D.

100% of devices affected

Question 19

Which of the following is the inspection frequency of the candela rating of visible appliances?

Options:

A.

Initial acceptance and quarterly

B.

Initial acceptance and semiannually

C.

Initial acceptance and if a malfunction occurs

D.

Initial acceptance and no further inspections

Question 20

Which three of the following are how a McCulloh transmitter should be inspected? (Choose three.)

Options:

A.

Distinct waterflow condition

B.

Physical condition

C.

System normal condition

D.

Verify location

Question 21

Which of the following signals takes highest priority?

Options:

A.

Pre-alarm

B.

Restoral

C.

Supervisory

D.

Trouble

Question 22

Load testing of the control unit's VRLA batteries reveals that they must be replaced. Which two of the following are requirements for the replacement of VRLA batteries? (Choose two.)

Options:

A.

Batteries shall be approved by the authority having jurisdiction.

B.

Batteries shall be listed by a nationally recognized testing laboratory.

C.

Batteries shall be marked with the month and year of manufacture.

D.

Batteries shall be the same make and model as those being replaced.

Question 23

Prior to any testing, all persons and facilities receiving signals and all occupants need to be notified of the testing to prevent which of the following issues?

Options:

A.

Critical system shutdown

B.

Elevator usage

C.

Facility evacuation

D.

Unnecessary response

Question 24

What is the periodic testing frequency of a control valve switch?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Question 25

How far away from the center line of the elevator door can a smoke detector be located?

Options:

A.

3 feet (1.0 meter)

B.

5 feet (1.5 meters)

C.

12 feet (3.7 meters)

D.

21 feet (6.4 meters)