Pre-Summer Sale 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: save70

Netapp NS0-185 Exam With Confidence Using Practice Dumps

Exam Code:
NS0-185
Exam Name:
NetApp Storage Installation Engineer - ONTAP Professional Exam
Certification:
Vendor:
Questions:
120
Last Updated:
Apr 14, 2026
Exam Status:
Stable
Netapp NS0-185

NS0-185: NCSIE ONTAP Exam 2025 Study Guide Pdf and Test Engine

Are you worried about passing the Netapp NS0-185 (NetApp Storage Installation Engineer - ONTAP Professional Exam) exam? Download the most recent Netapp NS0-185 braindumps with answers that are 100% real. After downloading the Netapp NS0-185 exam dumps training , you can receive 99 days of free updates, making this website one of the best options to save additional money. In order to help you prepare for the Netapp NS0-185 exam questions and verified answers by IT certified experts, CertsTopics has put together a complete collection of dumps questions and answers. To help you prepare and pass the Netapp NS0-185 exam on your first attempt, we have compiled actual exam questions and their answers. 

Our (NetApp Storage Installation Engineer - ONTAP Professional Exam) Study Materials are designed to meet the needs of thousands of candidates globally. A free sample of the CompTIA NS0-185 test is available at CertsTopics. Before purchasing it, you can also see the Netapp NS0-185 practice exam demo.

NetApp Storage Installation Engineer - ONTAP Professional Exam Questions and Answers

Question 1

After adding two nodes to an FC-enabled cluster, the storage administrator wants to ensure that existing LUNs can use paths on the new nodes.

What is required to complete this task?

Options:

A.

Use the storage port rescan command.

B.

Use the lun mapping add-reporting-nodes command.

C.

Use the lun bind create command.

D.

Rescan the bus on the hosts by using the rescan-scsi-bus.sh script.

Buy Now
Question 2

You have added two new AFF A250 nodes to an existing 4-node cluster with NetApp CN1610 cluster network switches. Although the nodes can join the cluster, the storage failover show command output shows that the NVRAM log is not synchronized, and it cannot reach the partner over an HA interconnect.

In this scenario, which two statements are true? (Choose two.)

Options:

A.

The AFF A250 requires switches with 40GbE port support.

B.

The AFF A250 uses different ports for the cluster and the HA interconnect.

C.

The AFF A250 requires switches with 25GbE port support.

D.

The AFF A250 uses the same port for the cluster and the HA interconnect.

Question 3

You have completed a base installation and system registration of an AFF A250 system, but you notice that you have one failed drive. Neither un-failing nor reseating the drive repaired it.

In this scenario, which two actions should you take? (Choose two.)

Options:

A.

Ask the customer to open a technical case with NetApp Support.

B.

Ask the customer for a drive with the same capacity and replace it.

C.

Run Active IQ Config Advisor to collect all the logs on the system.

D.

Power off the system until the drive has been replaced.