Commercial Mechanical Inspector Questions and Answers

Question 1

Floor furnaces shall not be closer than _____ inches to the ground.

Options:

A.

[option text not fully visible in the material you sent]

B.

[option text not fully visible in the material you sent]

C.

[option text not fully visible in the material you sent]

D.

12

Buy Now
Question 2

Why are two or more sets of construction documents, engineering calculations, diagrams, and other data required to be submitted with each application for a permit?

Options:

A.

To ensure that the project is completed in a timely manner.

B.

All sets are to be retained by the code official in order to have a spare set of construction documents for use by any subcontractors.

C.

All sets of documents are to be kept by the code official, and at least one set will serve as a backup set of documents in case the other is lost or misplaced.

D.

One set will be retained by the code official, and the other will be returned to the applicant and kept on the job site for reference while construction is in progress.

Question 3

When testing dampers located in corridors, the dampers shall demonstrate acceptable closure performance when subjected to _____ fpm velocity across the face of the damper using the UL 555 fire exposure test.

Options:

A.

75

B.

100

C.

150

D.

200

Question 4

Where located on a roof with a 5:12 slope, a level platform shall be provided along the access panel of the furnace at least _____ inches wide.

Options:

A.

[option text not fully visible in the material you sent]

B.

24

C.

30

D.

36

Question 5

Exhibit:

What hp is EF-2?

Options:

A.

1/2

B.

1

C.

1.5

D.

2

Question 6

The optional integral clearance reduction system is designed to meet which NFPA standard?

Options:

A.

33

B.

72

C.

92A

D.

96

Question 7

Which of the following is not a required mechanical inspection?

Options:

A.

Final

B.

Rough-in

C.

Underground

D.

Annual system test

Question 8

All exposed gas piping shall be kept above grade a minimum of _____ inches.

Options:

A.

3.5

B.

6

C.

8.5

D.

12

Question 9

Indoor combustion air shall be provided within:

Options:

A.

1 foot of the ceiling and 1 foot of the floor.

B.

1 foot of the ceiling and 2 feet of the floor.

C.

2 feet of the ceiling and 1 foot of the floor.

D.

2 feet of the ceiling and 2 feet of the floor.

Question 10

Exhaust is required for which of the following areas?

Options:

A.

Gambling casinos

B.

Office break rooms

C.

High school locker rooms

D.

Prison guard stations

Question 11

Given: Fabricated of type 430 stainless steel.

Optional type _____ stainless steel is available.

Options:

A.

301

B.

303

C.

304

D.

316

Question 12

Exhaust outlets that terminate at a temperature exceeding 600°F shall be designed as a:

Options:

A.

Class I duct.

B.

Class II duct.

C.

Class III duct.

D.

single-wall metal chimney.

Question 13

What is the maximum distance allowed below the design flood elevation from which ventilation may be obtained?

Options:

A.

0 inches

B.

6 inches

C.

1 foot

D.

2 feet

Question 14

When a permit is issued, the code requires that one set of approved plans and specifications be returned to the applicant.

This set of plans and specifications shall be:

Options:

A.

kept on the building site.

B.

returned to the architect.

C.

filed with the county clerk or jurisdiction to properly record the property.

D.

retained by the applicant for at least one year after the job is finished in the event modifications are made.

Question 15

When a furnace is installed in a 66-inch-high attic, the maximum distance from the passageway access to the furnace shall be _____ ft., measured along the centerline of the passageway.

Options:

A.

10

B.

15

C.

20

D.

50