Labour Day Special - Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: top65certs

Netapp NS0-194 Dumps

Page: 1 / 2
Total 60 questions

NetApp Certified Support Engineer (NCSE) Questions and Answers

Question 1

Which three techniques are used in ONTAP to improve storage efficiencies? (Choose three.)

Options:

A.

compression

B.

encryption

C.

compaction

D.

ADP

E.

thin provisioning

Question 2

Your Windows clients were able to access your CIFS SVM yesterday. Today they are no longer able to access the CIFS SVM on your NetApp cluster. Your IT security team just pushed out a new group policy to enhance security.

In this scenario, which statement is true?

Options:

A.

Your CIFS SVM is not using DNS.

B.

Your CIFS SVM is configured to use SMBv1 and SMBv2.

C.

Your CIFS SVM is configured for NFSv3 access.

D.

Your CIFS SVM is configured for the wrong domain.

Question 3

What is the consequence of a loss of connectivity between a Cloud Volumes ONTAP (CVO) instance and Cloud Manager for four or more days?

Options:

A.

The CVO instance sends an AutoSupport message.

B.

The CVO instance must be added back manually to Cloud Manager.

C.

Cloud Manager removes the CVO instance from its inventory.

D.

The CVO instance is stopped.

Question 4

A customer is showing disk utilization is at 100% in Active IQ even though there are low protocol operations on the controller. You review the data shown in the exhibit.

In this situation, what should you do?

Options:

A.

Replace disks 6b.34 and 6a.19.

B.

Add disks to the aggregate to bring down the average utilization.

C.

Replace disk 6b.39.

D.

Reseat shelf module B.

Question 5

Which NetApp HCI component communicates with activeiq.solidfire.com and the Cloud Data Services portal?

Options:

A.

the NetApp Element software vSphere plug-in

B.

the management node (mNode)

C.

the NetApp Trident software

D.

the NetApp Element software Management Interface

Question 6

Your customer's MetroCluster has generated a "DISK REDUNDANCY FAILED" message.

Netapp-EmA:

Tue Jan 14 04:12:12 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv' failed.

Tue Jan 14 04:12:13 CET [netapp-EmA:rv.connection.torndown:info]: HA interconnect: cfo_rv1 is torn down on NIC 1.

Tue Jan 14 04:12:13 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'1 failed.

Tue Jan 14 04:12:15 CET [netapp-EmA:rv.connection.torndown:info]: HA interconnect: cfo_rv2 is torn down on NIC 1.

Tue Jan 14 04:12:18 CET [netapp-EmA:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'2 failed.

Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111161] was removed

Tue Jan 14 04:12:19 CET [netapp-EmA:bridge.removed:info]: FC-to_SAS bridge siteB_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111160] was removed

Netapp-EmB:

Tue Jan 14 04:12:12 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv' failed.

Tue Jan 14 04:12:12 CET [netapp-EmB:rv.connection.torndown:info]: HA interconnect: cfo_rv2 is torn down on NIC 1.

Tue Jan 14 04:12:13 CET [netapp-EmB:rv.connection.torndown:info]: HA interconnect: cfo_rv1 is torn down on NIC 1.

Tue Jan 14 04:12:13 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'1 failed.

Tue Jan 14 04:12:18 CET [netapp-EmB:cf.rv.notConnected:error]: HA interconnect: Connection for 'cfo_rv'2 failed.

Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:13.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111167] was removed

Tue Jan 14 04:12:19 CET [netapp-EmB:bridge.removed:info]: FC-to_SAS bridge siteA_2:5.126L0 [ATTO FibreBridge6500N 1.61] S/N [FB7500N111164] was removed

Referring to the messages shown in the exhibit for each node, which component is causing the problem?

Options:

A.

the ATTO bridge on siteB_2

B.

the SAN switch siteA_2

C.

the SAN switch siteB_2

D.

the ISL between siteA and site B

Question 7

A customer is trying to enable NVMe and wants to use the FC adapters in the controllers but cannot enable the protocol.

Referring to the exhibit, what is causing the problem?

Options:

A.

There are no FC adapters installed with the speed set to 32Gbps.

B.

There are no FC adapters installed with a physical protocol set to NVMe.

C.

There are no FC adapters installed with a max-speed of 32Gbps.

D.

There are no FC adapters installed with a media type of NVMe.

Question 8

A disaster causes a FlexGroup volume to be unrecoverable, but it was protected by a SnapMirror relationship. You solve the issue, and the source is operational. Now, you want to return to serving the data from the original source.

In this scenario, what do you do next?

Options:

A.

Initialize the SnapMirror relationship.

B.

Restore data from a backup copy.

C.

Perform a SnapMirror update.

D.

Delete the SnapMirror relationship.

Question 9

While troubleshooting client access issues to a CIFS share, you notice that the issue only occurs when the data LIF that the clients are accessing is on a specific node in the cluster.

In this scenario, which configuration should you review to determine why this issue is happening?

Options:

A.

cluster health

B.

Kerberos

C.

share path

D.

export policies

Page: 1 / 2
Total 60 questions