Summer Special Limited Time 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 60certs

Checkpoint 156-835 Dumps

Page: 1 / 2
Total 64 questions

Check Point Certified Maestro Expert Questions and Answers

Question 1

What is the max amount of Orchestrators in Dual-site setup?

Options:

A.

2 per Security Group

B.

4 per Security Group

C.

2

D.

4

Question 2

What kinds of transceivers are supported on Orchestrator MHO-170?

Options:

A.

QSFP. QSFP28

B.

SFP. SFP+. SFP28

C.

SFP+, SFP28. QSFP

D.

SFP. QSFP, QSFP28

Question 3

What is the default range of physical ports for downlinks on Orchestrator MHO-170?

Options:

A.

3 - 16

B.

17 - 31

C.

25 - 32

D.

1 - 16

Question 4

What is the distribution mode?

Options:

A.

Distribution mode is the same as QSFP mode

B.

Distribution mode is how the Orchestrator distributes traffic in between Security Groups

C.

Distribution mode means selected algorithm for traffic distribution in between Orchestrators

D.

Distribution mode means selected algorithm for traffic distribution in between Appliances

Question 5

What cannot be a reason for "Failed to get remote orchestrator interfaces" error message, when clicking on "Orchestrator" in WebUI?

Options:

A.

Remote orchestrator has no empty interfaces

B.

One orchestrator only, but Orchestrator amount is 2 or no Sync in between orchestrators

C.

No Sync between orchestrators

D.

D.Single orchestrator environment, but configured Orchestrator amount is 2

Question 6

In order to set Site (chassis) priority per VS, following command should be used:

Options:

A.

From given VS context: set chassis high-availability vs chassis_priority

B.

From given VSO context: set chassis high-availability vs chassis_priority

C.

From any VS context: set chassis high-availability vs chassis_priority

D.

From VSO context: set chassis high-availability vs chassis_priority

Question 7

There are two 10Gbps dual-port NIC installed on a 6800 appliance. Which interfaces should be connected to Orchestrator 1 for downlinks' intra-orchestrator redundancy when using two Orchestrators?

Options:

A.

Port 1 in Slot 1 and Port 2 in Slot 1

B.

Port 1 in Slot 2 and Port 2 in Slot 1

C.

Any pair of available ports

D.

Port 1 in Slot 1 and Port 1 in Slot 2

Question 8

One single Appliance supports 1M concurrent connections. How many concurrent connections will support Security Group of 2 Appliances?

Options:

A.

2M

B.

500K

C.

4M

D.

1M

Question 9

Where shouldsx_api_ports_dump,pycommand be ran?

Options:

A.

Orchestrator

B.

SMO Appliance

C.

Management server

D.

Security Group

Page: 1 / 2
Total 64 questions